Compact, accurate, efficient, robust, and easy-to-use SDI-12 bubbler
sensor for water level monitoring.
Users' Benefits:
- AccurateMeets and exceeds USGS guidelines for water level
accuracy, and will not drift over time
- Complete SolutionCombining the CBS with an EPS-50 bubble
chamber reduces the influence of wave action and prevents unnecessary
noise in your data
- Low MaintenanceNo desiccant required; 5 year life expected
based on 1 minute intervalsno pump maintenance or lubrication
required
- Easy-to-Start/Easy-to-InstallAll programming can be completed
using DIP switches; connect into existing platforms using 3/8"
O.D. or 4mm O.D. measuring tube (no adapters required)
- Compact SizeOptimization of air volume required for measurement
allows utilization of a small, but powerful spur gear
motor that fits into a compact packageno compressed gas tank is
required
- Low PowerIntelligent pumping strategy compares the previous
measurement to the actual pressure at the current measurement, and optimizes
the pumping time depending on the difference (i.e., small
changes in level are measured with very short pump cycles)
Additional Features:
- Manual purge button easily accessed from the face of the unit, or
purge function available via SDI-12 command
- SDI-12 or 4-20 mA Output
- Compatible with 12V or 24V applications
- Overload protection powers the unit off if pressure or current is
too high
- No offset calibration required
- All calibration data is stored on the pressure cell so field replacement
is easily accomplished
Product Data:
| Specs |
|
| Measuring range: |
0-50 ft (0-15 m) |
| Accuracy of pressure measurement: |
Standard 0-50 ft range version:
±0.02 ft
High accuracy 0-50 ft range version:
0-15 ft: ±0.01 ft
15-35 ft: ±0.065% of reading
35-50 ft: ±0.02 ft |
| Resolution: |
0.003 ft / 0.014 psi |
| Units: |
ft, psi, m, bar |
| Measuring interval: |
1 min to 24 hr |
| Max rate of level change: |
3 ft/min |
| Output: |
SDI-12
4-20 mA |
| Power supply: |
10-30 V DC |
| Power consumption: |
15 min. measurement interval 25 mAh/day
1 min. measurement interval 320 mAh/day |
| Compatible tubing: |
1/8 in., 2 mm or 4 mm ID |
| Temperature range: |
-4 to 140°F (-20 to 60°C) |
| Dimensions: |
6.5 in. x 8.1 in. x 4.6 in. (L x W x H) |
| Weight: |
3.3 lbs. |
| Integrated purge function |
|
| Overload protection |
|
|
|